5.13 Sensor & Output
a) b)
c)
a) Set Sensor
-Use : check external sensor 1 ~ 16.
- Type : Set type of sensor. To change type just click each buttons.
- ‘NO(Normal Open)’ type on usual time.
- 'NC(Normal Close)’ when control output.
- Record : set number of record frame when sensor detected.
- Delay : Set sensor detecting delay time. It works by the second.
- Output : Type control output number. If you type 4 on sensor 3, control button 4 will work when sensor 3
detects.
- Duration : Set the time value of ignoring sensor signal after sensor detects.
b) Set Control output
- Use : Set control output 1 ~ 16.
- Name : Type the name of controller .
- Auto ON/OFF Time : Set on/off time for each controller.
c) Other setup
- Sensor # for Alarm Output (Siren) : When external alarm sensor detects, control output no. 16 works.
- Transmission Sensor : When sensor detects, it delivers images to client PC where emergency agent works.
- Transmission Duration : Set transmission duration of image.