16.5.2.1c
3 Phs Voltage (ac)
97V to 134V, 360Hz
Apply for 5 mins each test
EAWF115_VABN3P360
16.5.2.1c
3 Phs Voltage (ac)
97V to 134V, 800Hz
Apply for 5 mins each test
EAWF115_VABN3P800
16.5.2.2
Momentary Undervoltage (ac)
10V and 60V, 360Hz
Apply for 7 seconds each test
EAWF115_VUND360
16.5.2.2
Momentary Undervoltage (ac)
10V and 60V, 800Hz
Apply for 7 seconds each test
EAWF115_VUND800
16.5.2.3
Abnormal Transients (ac)
16.5.2.3.1 - Abnormal Voltage surge
148V to 180V, 360Hz
Figure 16.5 - apply at 10 sec intervals
EAWF115_AVSUR360
16.5.2.3.1 - Abnormal Voltage surge
148V to 180V, 800Hz
Figure 16.5 - apply at 10 sec intervals
EAWF115_AVSUR800